  "id": "wearable-accuracy",
  "module": "A",
  "version": "2026-11-17.1",
  "title": {
    "de": "Wearable-Genauigkeit: Studienregister",
    "en": "Wearable accuracy: study register"
  },
  "description": {
    "de": "Validierungsstudien, Meta-Analysen und Reviews zu Schlaf, Puls, HRV, SpO2, Schritten, Energieverbrauch und Herzrhythmus – Gerät, Referenz, Situation, Fehlermaß in Originalmetrik.",
    "en": "Validation studies, meta-analyses and reviews on sleep, heart rate, HRV, SpO2, steps, energy expenditure and heart rhythm – device, reference, situation, error measure in the original metric."
  },
  "url": "https://syrax.site/de/daten/wearable-genauigkeit",
  "url_en": "https://syrax.site/en/daten/wearable-genauigkeit",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "published": "2026-11-17",
  "modified": "2026-11-17",
  "temporal_coverage": "2017/2026",
  "spatial_coverage": {
    "de": "International (Studienorte weltweit)",
    "en": "International (study sites worldwide)"
  },
  "measurement_technique": {
    "de": "Manuelle Extraktion aus peer-reviewten Studien (Abstract/Volltext gekennzeichnet)",
    "en": "Manual extraction from peer-reviewed studies (abstract/full text flagged)"
  },
  "review": {
    "status": "approved",
    "kind": "redaktion",
    "by": "Syrax Data & Research (Redaktion)",
    "at": "2026-11-17",
    "note": {
      "de": "Jede Zeile gegen Abstract bzw. Volltext geprüft.",
      "en": "Every row checked against abstract or full text."
    }
  },
  "publishable": true,
  "sources": [
    {
      "id": "europepmc",
      "org": "Europe PMC (EMBL-EBI)",
      "title": "Europe PMC RESTful Web Service – bibliografische Metadaten und Abstracts",
      "url": "https://europepmc.org/RestfulWebService",
      "license": "Metadaten frei nutzbar; Abstracts und Volltexte unterliegen der Lizenz des jeweiligen Artikels",
      "attribution": "Metadaten: Europe PMC; Ergebnisse: jeweilige Originalstudie (DOI)",
      "retrieved": "2026-11-17"
    }
  ],
  "downloads": [
    "https://syrax.site/daten/wearable-genauigkeit.csv",
    "https://syrax.site/daten/wearable-genauigkeit.json"
  ],
  "attribution": "Syrax (https://syrax.site/de/daten/wearable-genauigkeit), CC BY 4.0; Metadaten: Europe PMC; Ergebnisse: jeweilige Originalstudie (DOI)",
  "rows": [
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Apple Watch S6",
      "metric_area": "schlaf",
      "metric_de": "Schlaf/Wach-Erkennung",
      "metric_en": "Sleep/wake detection",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "88 % (κ = 0.30)",
      "value_en": "88 % (κ = 0.30)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Garmin Forerunner 245 Music",
      "metric_area": "schlaf",
      "metric_de": "Schlaf/Wach-Erkennung",
      "metric_en": "Sleep/wake detection",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "89 % (κ = 0.35)",
      "value_en": "89 % (κ = 0.35)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Polar Vantage V",
      "metric_area": "schlaf",
      "metric_de": "Schlaf/Wach-Erkennung",
      "metric_en": "Sleep/wake detection",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "87 % (κ = 0.44)",
      "value_en": "87 % (κ = 0.44)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Oura Ring Gen 2",
      "metric_area": "schlaf",
      "metric_de": "Schlaf/Wach-Erkennung",
      "metric_en": "Sleep/wake detection",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "89 % (κ = 0.51)",
      "value_en": "89 % (κ = 0.51)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "WHOOP 3.0",
      "metric_area": "schlaf",
      "metric_de": "Schlaf/Wach-Erkennung",
      "metric_en": "Sleep/wake detection",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "86 % (κ = 0.44)",
      "value_en": "86 % (κ = 0.44)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Somfit",
      "metric_area": "schlaf",
      "metric_de": "Schlaf/Wach-Erkennung",
      "metric_en": "Sleep/wake detection",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "87 % (κ = 0.48)",
      "value_en": "87 % (κ = 0.48)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Apple Watch S6",
      "metric_area": "schlaf",
      "metric_de": "Schlafphasen (Wach, leicht, tief, REM)",
      "metric_en": "Sleep stages (wake, light, deep, REM)",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "53 % (κ = 0.20)",
      "value_en": "53 % (κ = 0.20)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Garmin Forerunner 245 Music",
      "metric_area": "schlaf",
      "metric_de": "Schlafphasen (Wach, leicht, tief, REM)",
      "metric_en": "Sleep stages (wake, light, deep, REM)",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "50 % (κ = 0.25)",
      "value_en": "50 % (κ = 0.25)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Polar Vantage V",
      "metric_area": "schlaf",
      "metric_de": "Schlafphasen (Wach, leicht, tief, REM)",
      "metric_en": "Sleep stages (wake, light, deep, REM)",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "51 % (κ = 0.28)",
      "value_en": "51 % (κ = 0.28)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Oura Ring Gen 2",
      "metric_area": "schlaf",
      "metric_de": "Schlafphasen (Wach, leicht, tief, REM)",
      "metric_en": "Sleep stages (wake, light, deep, REM)",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "61 % (κ = 0.43)",
      "value_en": "61 % (κ = 0.43)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "WHOOP 3.0",
      "metric_area": "schlaf",
      "metric_de": "Schlafphasen (Wach, leicht, tief, REM)",
      "metric_en": "Sleep stages (wake, light, deep, REM)",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "60 % (κ = 0.44)",
      "value_en": "60 % (κ = 0.44)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Somfit",
      "metric_area": "schlaf",
      "metric_de": "Schlafphasen (Wach, leicht, tief, REM)",
      "metric_en": "Sleep stages (wake, light, deep, REM)",
      "context": "Sleep",
      "error_type_de": "Übereinstimmung (Epochen)",
      "error_type_en": "Agreement (epochs)",
      "value_de": "65 % (κ = 0.52)",
      "value_en": "65 % (κ = 0.52)",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Geräte mit Messung im Schlaf",
      "metric_area": "herzfrequenz",
      "metric_de": "Puls im Schlaf",
      "metric_en": "Heart rate during sleep",
      "context": "Sleep",
      "error_type_de": "relative Übereinstimmung",
      "error_type_en": "relative agreement",
      "value_de": "hoch",
      "value_en": "high",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "miller-2022-sechs-wearables",
      "first_author_year": "Miller 2022",
      "title": "A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults",
      "journal": "Sensors",
      "year": 2022,
      "design": "validierung",
      "doi": "10.3390/s22166317",
      "doi_url": "https://doi.org/10.3390/s22166317",
      "pmid": "36016077",
      "device": "Geräte mit Messung im Schlaf",
      "metric_area": "hrv",
      "metric_de": "HRV (RMSSD) im Schlaf",
      "metric_en": "HRV (RMSSD) during sleep",
      "context": "Sleep",
      "error_type_de": "relative Übereinstimmung",
      "error_type_en": "relative agreement",
      "value_de": "mittel bis hoch",
      "value_en": "moderate to high",
      "extraction": "abstract+volltext",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "chinoy-2021-sieben-schlaftracker",
      "first_author_year": "Chinoy 2021",
      "title": "Performance of seven consumer sleep-tracking devices compared with polysomnography",
      "journal": "Sleep",
      "year": 2021,
      "design": "validierung",
      "doi": "10.1093/sleep/zsaa291",
      "doi_url": "https://doi.org/10.1093/sleep/zsaa291",
      "pmid": "33378539",
      "device": "7 Geräte (Bereich)",
      "metric_area": "schlaf",
      "metric_de": "Schlaf erkannt",
      "metric_en": "Sleep detected",
      "context": "Sleep",
      "error_type_de": "Sensitivität (Epochen)",
      "error_type_en": "Sensitivity (epochs)",
      "value_de": "≥ 0,93",
      "value_en": "≥ 0.93",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "chinoy-2021-sieben-schlaftracker",
      "first_author_year": "Chinoy 2021",
      "title": "Performance of seven consumer sleep-tracking devices compared with polysomnography",
      "journal": "Sleep",
      "year": 2021,
      "design": "validierung",
      "doi": "10.1093/sleep/zsaa291",
      "doi_url": "https://doi.org/10.1093/sleep/zsaa291",
      "pmid": "33378539",
      "device": "7 Geräte (Bereich)",
      "metric_area": "schlaf",
      "metric_de": "Wach erkannt",
      "metric_en": "Wake detected",
      "context": "Sleep",
      "error_type_de": "Spezifität (Epochen)",
      "error_type_en": "Specificity (epochs)",
      "value_de": "0,18–0,54",
      "value_en": "0.18–0.54",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "kainec-2024-fuenf-schlaftracker",
      "first_author_year": "Kainec 2024",
      "title": "Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography",
      "journal": "Sensors",
      "year": 2024,
      "design": "validierung",
      "doi": "10.3390/s24020635",
      "doi_url": "https://doi.org/10.3390/s24020635",
      "pmid": "38276327",
      "device": "Garmin Vivosmart",
      "metric_area": "schlaf",
      "metric_de": "Gesamtschlafzeit",
      "metric_en": "Total sleep time",
      "context": "Sleep",
      "error_type_de": "Bias gegen PSG (qualitativ)",
      "error_type_en": "Bias vs PSG (qualitative)",
      "value_de": "schlechter als Aktigrafie",
      "value_en": "worse than actigraphy",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "kainec-2024-fuenf-schlaftracker",
      "first_author_year": "Kainec 2024",
      "title": "Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography",
      "journal": "Sensors",
      "year": 2024,
      "design": "validierung",
      "doi": "10.3390/s24020635",
      "doi_url": "https://doi.org/10.3390/s24020635",
      "pmid": "38276327",
      "device": "Fitbit Inspire, Fitbit Versa, Oura Ring, Withings Mat",
      "metric_area": "schlaf",
      "metric_de": "Gesamtschlafzeit",
      "metric_en": "Total sleep time",
      "context": "Sleep",
      "error_type_de": "Bias gegen PSG (qualitativ)",
      "error_type_en": "Bias vs PSG (qualitative)",
      "value_de": "vergleichbar mit Aktigrafie",
      "value_en": "comparable to actigraphy",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "kainec-2024-fuenf-schlaftracker",
      "first_author_year": "Kainec 2024",
      "title": "Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography",
      "journal": "Sensors",
      "year": 2024,
      "design": "validierung",
      "doi": "10.3390/s24020635",
      "doi_url": "https://doi.org/10.3390/s24020635",
      "pmid": "38276327",
      "device": "alle 5 Geräte",
      "metric_area": "schlaf",
      "metric_de": "REM-Schlaf",
      "metric_en": "REM sleep",
      "context": "Sleep",
      "error_type_de": "Bias gegen PSG (qualitativ)",
      "error_type_en": "Bias vs PSG (qualitative)",
      "value_de": "niedrig",
      "value_en": "low",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "lee-2025-metaanalyse-schlaftracker",
      "first_author_year": "Lee 2025",
      "title": "Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis",
      "journal": "Journal of Clinical Sleep Medicine",
      "year": 2025,
      "design": "meta-analyse",
      "doi": "10.5664/jcsm.11460",
      "doi_url": "https://doi.org/10.5664/jcsm.11460",
      "pmid": "39484805",
      "device": "gepoolt (Handgelenk-Tracker)",
      "metric_area": "schlaf",
      "metric_de": "Gesamtschlafzeit",
      "metric_en": "Total sleep time",
      "context": "Sleep",
      "error_type_de": "mittlere Differenz (min, 95-%-KI)",
      "error_type_en": "mean difference (min, 95% CI)",
      "value_de": "−16,9 [−26,3; −7,4]",
      "value_en": "−16.9 [−26.3; −7.4]",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "lee-2025-metaanalyse-schlaftracker",
      "first_author_year": "Lee 2025",
      "title": "Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis",
      "journal": "Journal of Clinical Sleep Medicine",
      "year": 2025,
      "design": "meta-analyse",
      "doi": "10.5664/jcsm.11460",
      "doi_url": "https://doi.org/10.5664/jcsm.11460",
      "pmid": "39484805",
      "device": "gepoolt (Handgelenk-Tracker)",
      "metric_area": "schlaf",
      "metric_de": "Schlafeffizienz",
      "metric_en": "Sleep efficiency",
      "context": "Sleep",
      "error_type_de": "mittlere Differenz (%-Punkte, 95-%-KI)",
      "error_type_en": "mean difference (percentage points, 95% CI)",
      "value_de": "−4,7 [−7,1; −2,3]",
      "value_en": "−4.7 [−7.1; −2.3]",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "lee-2025-metaanalyse-schlaftracker",
      "first_author_year": "Lee 2025",
      "title": "Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis",
      "journal": "Journal of Clinical Sleep Medicine",
      "year": 2025,
      "design": "meta-analyse",
      "doi": "10.5664/jcsm.11460",
      "doi_url": "https://doi.org/10.5664/jcsm.11460",
      "pmid": "39484805",
      "device": "gepoolt (Handgelenk-Tracker)",
      "metric_area": "schlaf",
      "metric_de": "Einschlafdauer",
      "metric_en": "Sleep latency",
      "context": "Sleep",
      "error_type_de": "mittlere Differenz (min, 95-%-KI)",
      "error_type_en": "mean difference (min, 95% CI)",
      "value_de": "+2,6 [0,6; 4,5]",
      "value_en": "+2.6 [0.6; 4.5]",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "lee-2025-metaanalyse-schlaftracker",
      "first_author_year": "Lee 2025",
      "title": "Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis",
      "journal": "Journal of Clinical Sleep Medicine",
      "year": 2025,
      "design": "meta-analyse",
      "doi": "10.5664/jcsm.11460",
      "doi_url": "https://doi.org/10.5664/jcsm.11460",
      "pmid": "39484805",
      "device": "gepoolt (Handgelenk-Tracker)",
      "metric_area": "schlaf",
      "metric_de": "Wachzeit nach dem Einschlafen",
      "metric_en": "Wake after sleep onset",
      "context": "Sleep",
      "error_type_de": "mittlere Differenz (min, 95-%-KI)",
      "error_type_en": "mean difference (min, 95% CI)",
      "value_de": "+13,3 [4,5; 22,0]",
      "value_en": "+13.3 [4.5; 22.0]",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "agostinho-2026-review-schlaftracker",
      "first_author_year": "Agostinho 2026",
      "title": "Are Wearable Sleep-Tracking Devices Reliable Alternatives to Polysomnography? A Systematic Review and Meta-Analysis",
      "journal": "Behavioral Sleep Medicine",
      "year": 2026,
      "design": "meta-analyse",
      "doi": "10.1080/15402002.2026.2673893",
      "doi_url": "https://doi.org/10.1080/15402002.2026.2673893",
      "pmid": "42175611",
      "device": "gepoolt",
      "metric_area": "schlaf",
      "metric_de": "Gesamtschlafzeit, Schlafeffizienz, Wachzeit",
      "metric_en": "Total sleep time, sleep efficiency, wake",
      "context": "Sleep",
      "error_type_de": "Richtung der Abweichung",
      "error_type_en": "Direction of bias",
      "value_de": "TST/SE überschätzt, WASO unterschätzt",
      "value_en": "TST/SE over-, WASO underestimated",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "shcherbina-2017-sieben-handgelenk-tracker",
      "first_author_year": "Shcherbina 2017",
      "title": "Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort",
      "journal": "Journal of Personalized Medicine",
      "year": 2017,
      "design": "validierung",
      "doi": "10.3390/jpm7020003",
      "doi_url": "https://doi.org/10.3390/jpm7020003",
      "pmid": "28538708",
      "device": "6 von 7 Geräten",
      "metric_area": "herzfrequenz",
      "metric_de": "Puls",
      "metric_en": "Heart rate",
      "context": "Exercise",
      "error_type_de": "Median-Fehler (Radfahren)",
      "error_type_en": "median error (cycling)",
      "value_de": "< 5 %",
      "value_en": "< 5 %",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "shcherbina-2017-sieben-handgelenk-tracker",
      "first_author_year": "Shcherbina 2017",
      "title": "Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort",
      "journal": "Journal of Personalized Medicine",
      "year": 2017,
      "design": "validierung",
      "doi": "10.3390/jpm7020003",
      "doi_url": "https://doi.org/10.3390/jpm7020003",
      "pmid": "28538708",
      "device": "alle 7 Geräte",
      "metric_area": "energieverbrauch",
      "metric_de": "Energieverbrauch",
      "metric_en": "Energy expenditure",
      "context": "mixed",
      "error_type_de": "Fehler",
      "error_type_en": "error",
      "value_de": "kein Gerät < 20 %",
      "value_en": "no device < 20%",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "bent-2020-ursachen-pulsfehler",
      "first_author_year": "Bent 2020",
      "title": "Investigating sources of inaccuracy in wearable optical heart rate sensors",
      "journal": "npj Digital Medicine",
      "year": 2020,
      "design": "validierung",
      "doi": "10.1038/s41746-020-0226-6",
      "doi_url": "https://doi.org/10.1038/s41746-020-0226-6",
      "pmid": "32047863",
      "device": "Wearables (gepoolt)",
      "metric_area": "herzfrequenz",
      "metric_de": "Puls: Aktivität vs. Ruhe",
      "metric_en": "Heart rate: activity vs rest",
      "context": "mixed",
      "error_type_de": "absoluter Fehler, relativ",
      "error_type_en": "absolute error, relative",
      "value_de": "+30 % bei Aktivität",
      "value_en": "+30% during activity",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "stone-2021-ruhepuls-hrv",
      "first_author_year": "Stone 2021",
      "title": "Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability",
      "journal": "Frontiers in Sports and Active Living",
      "year": 2021,
      "design": "validierung",
      "doi": "10.3389/fspor.2021.585870",
      "doi_url": "https://doi.org/10.3389/fspor.2021.585870",
      "pmid": "33733234",
      "device": "CameraHRV (App)",
      "metric_area": "herzfrequenz",
      "metric_de": "Ruhepuls",
      "metric_en": "Resting heart rate",
      "context": "Rest",
      "error_type_de": "MAPE",
      "error_type_en": "MAPE",
      "value_de": "17,26 %",
      "value_en": "17.26%",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "stone-2021-ruhepuls-hrv",
      "first_author_year": "Stone 2021",
      "title": "Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability",
      "journal": "Frontiers in Sports and Active Living",
      "year": 2021,
      "design": "validierung",
      "doi": "10.3389/fspor.2021.585870",
      "doi_url": "https://doi.org/10.3389/fspor.2021.585870",
      "pmid": "33733234",
      "device": "HRV4Training (App)",
      "metric_area": "herzfrequenz",
      "metric_de": "Ruhepuls",
      "metric_en": "Resting heart rate",
      "context": "Rest",
      "error_type_de": "MAPE",
      "error_type_en": "MAPE",
      "value_de": "2,34 %",
      "value_en": "2.34%",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "stone-2021-ruhepuls-hrv",
      "first_author_year": "Stone 2021",
      "title": "Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability",
      "journal": "Frontiers in Sports and Active Living",
      "year": 2021,
      "design": "validierung",
      "doi": "10.3389/fspor.2021.585870",
      "doi_url": "https://doi.org/10.3389/fspor.2021.585870",
      "pmid": "33733234",
      "device": "OURA",
      "metric_area": "hrv",
      "metric_de": "RMSSD in Ruhe",
      "metric_en": "RMSSD at rest",
      "context": "Rest",
      "error_type_de": "MAPE (CCC)",
      "error_type_en": "MAPE (CCC)",
      "value_de": "6,84 % (CCC 0,91)",
      "value_en": "6.84% (CCC 0.91)",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "stone-2021-ruhepuls-hrv",
      "first_author_year": "Stone 2021",
      "title": "Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability",
      "journal": "Frontiers in Sports and Active Living",
      "year": 2021,
      "design": "validierung",
      "doi": "10.3389/fspor.2021.585870",
      "doi_url": "https://doi.org/10.3389/fspor.2021.585870",
      "pmid": "33733234",
      "device": "HRV4Training (App)",
      "metric_area": "hrv",
      "metric_de": "RMSSD in Ruhe",
      "metric_en": "RMSSD at rest",
      "context": "Rest",
      "error_type_de": "MAPE (CCC)",
      "error_type_en": "MAPE (CCC)",
      "value_de": "4,10 % (CCC 0,98)",
      "value_en": "4.10% (CCC 0.98)",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "stone-2021-ruhepuls-hrv",
      "first_author_year": "Stone 2021",
      "title": "Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability",
      "journal": "Frontiers in Sports and Active Living",
      "year": 2021,
      "design": "validierung",
      "doi": "10.3389/fspor.2021.585870",
      "doi_url": "https://doi.org/10.3389/fspor.2021.585870",
      "pmid": "33733234",
      "device": "CameraHRV (App)",
      "metric_area": "hrv",
      "metric_de": "RMSSD in Ruhe",
      "metric_en": "RMSSD at rest",
      "context": "Rest",
      "error_type_de": "MAPE (CCC)",
      "error_type_en": "MAPE (CCC)",
      "value_de": "112,36 % (CCC 0,04)",
      "value_en": "112.36% (CCC 0.04)",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "pipek-2021-apple-watch-spo2",
      "first_author_year": "Pipek 2021",
      "title": "Comparison of SpO2 and heart rate values on Apple Watch and conventional commercial oximeters devices in patients with lung disease",
      "journal": "Scientific Reports",
      "year": 2021,
      "design": "validierung",
      "doi": "10.1038/s41598-021-98453-3",
      "doi_url": "https://doi.org/10.1038/s41598-021-98453-3",
      "pmid": "34556765",
      "device": "Apple Watch Series 6",
      "metric_area": "spo2",
      "metric_de": "Sauerstoffsättigung",
      "metric_en": "Oxygen saturation",
      "context": "Rest",
      "error_type_de": "Korrelation r",
      "error_type_en": "correlation r",
      "value_de": "0,81",
      "value_en": "0.81",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "pipek-2021-apple-watch-spo2",
      "first_author_year": "Pipek 2021",
      "title": "Comparison of SpO2 and heart rate values on Apple Watch and conventional commercial oximeters devices in patients with lung disease",
      "journal": "Scientific Reports",
      "year": 2021,
      "design": "validierung",
      "doi": "10.1038/s41598-021-98453-3",
      "doi_url": "https://doi.org/10.1038/s41598-021-98453-3",
      "pmid": "34556765",
      "device": "Apple Watch Series 6",
      "metric_area": "herzfrequenz",
      "metric_de": "Puls",
      "metric_en": "Heart rate",
      "context": "Rest",
      "error_type_de": "Korrelation r",
      "error_type_en": "correlation r",
      "value_de": "0,995",
      "value_en": "0.995",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "fokkema-2017-zehn-tracker-schritte",
      "first_author_year": "Fokkema 2017",
      "title": "Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed",
      "journal": "Medicine & Science in Sports & Exercise",
      "year": 2017,
      "design": "validierung",
      "doi": "10.1249/mss.0000000000001146",
      "doi_url": "https://doi.org/10.1249/mss.0000000000001146",
      "pmid": "28319983",
      "device": "10 Tracker (Bereich)",
      "metric_area": "schritte",
      "metric_de": "Schritte",
      "metric_en": "Steps",
      "context": "Walking (treadmill)",
      "error_type_de": "mittlere Abweichung zur Handzählung",
      "error_type_en": "mean difference from hand count",
      "value_de": "0,0–26,4 %",
      "value_en": "0.0–26.4%",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "fuller-2020-review-158-studien",
      "first_author_year": "Fuller 2020",
      "title": "Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review",
      "journal": "JMIR mHealth and uHealth",
      "year": 2020,
      "design": "review",
      "doi": "10.2196/18694",
      "doi_url": "https://doi.org/10.2196/18694",
      "pmid": "32897239",
      "device": "9 Marken",
      "metric_area": "schritte",
      "metric_de": "Schritte (Labor)",
      "metric_en": "Steps (lab)",
      "context": "mixed",
      "error_type_de": "Bewertung der Autoren",
      "error_type_en": "authors' assessment",
      "value_de": "genau: Fitbit, Apple Watch, Samsung",
      "value_en": "accurate: Fitbit, Apple Watch, Samsung",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "fuller-2020-review-158-studien",
      "first_author_year": "Fuller 2020",
      "title": "Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review",
      "journal": "JMIR mHealth and uHealth",
      "year": 2020,
      "design": "review",
      "doi": "10.2196/18694",
      "doi_url": "https://doi.org/10.2196/18694",
      "pmid": "32897239",
      "device": "9 Marken",
      "metric_area": "energieverbrauch",
      "metric_de": "Energieverbrauch",
      "metric_en": "Energy expenditure",
      "context": "mixed",
      "error_type_de": "Bewertung der Autoren",
      "error_type_en": "authors' assessment",
      "value_de": "keine Marke genau",
      "value_en": "no brand accurate",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "germini-2022-review-65-studien",
      "first_author_year": "Germini 2022",
      "title": "Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature",
      "journal": "Journal of Medical Internet Research",
      "year": 2022,
      "design": "review",
      "doi": "10.2196/30791",
      "doi_url": "https://doi.org/10.2196/30791",
      "pmid": "35060915",
      "device": "alle untersuchten Marken",
      "metric_area": "energieverbrauch",
      "metric_de": "Energieverbrauch",
      "metric_en": "Energy expenditure",
      "context": "mixed",
      "error_type_de": "MAPE",
      "error_type_en": "MAPE",
      "value_de": "> 30 %",
      "value_en": "> 30 %",
      "extraction": "abstract",
      "checked": "2026-11-17"
    },
    {
      "study_slug": "perez-2019-apple-heart-study",
      "first_author_year": "Perez 2019",
      "title": "Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation",
      "journal": "New England Journal of Medicine",
      "year": 2019,
      "design": "kohorte",
      "doi": "10.1056/nejmoa1901183",
      "doi_url": "https://doi.org/10.1056/nejmoa1901183",
      "pmid": "31722151",
      "device": "Apple Watch",
      "metric_area": "herzrhythmus",
      "metric_de": "Hinweis auf Vorhofflimmern",
      "metric_en": "Atrial fibrillation notification",
      "context": "Free living",
      "error_type_de": "positiver Vorhersagewert",
      "error_type_en": "positive predictive value",
      "value_de": "0,84 (95-%-KI 0,76–0,92)",
      "value_en": "0.84 (95% CI 0.76–0.92)",
      "extraction": "abstract",
      "checked": "2026-11-17"
    }
  ]
}