Sleep: How accurate are wearables? Studies at a glance

Sleep trackers are tested against polysomnography (PSG) in a sleep lab. They reliably detect whether someone is asleep, but much less well when someone lies awake. Agreement for individual sleep stages is rough.

5 studies · 22 results

Results

22 results

DeviceMetricSituationError measure (original)ResultStudy
Apple Watch S6Sleep/wake detectionSleepSleepAgreement (epochs)88 % (κ = 0.30)Miller et al. 2022Validation study · abstract + full text
Garmin Forerunner 245 MusicSleep/wake detectionSleepSleepAgreement (epochs)89 % (κ = 0.35)Miller et al. 2022Validation study · abstract + full text
Polar Vantage VSleep/wake detectionSleepSleepAgreement (epochs)87 % (κ = 0.44)Miller et al. 2022Validation study · abstract + full text
Oura Ring Gen 2Sleep/wake detectionSleepSleepAgreement (epochs)89 % (κ = 0.51)Miller et al. 2022Validation study · abstract + full text
WHOOP 3.0Sleep/wake detectionSleepSleepAgreement (epochs)86 % (κ = 0.44)Miller et al. 2022Validation study · abstract + full text
SomfitSleep/wake detectionSleepSleepAgreement (epochs)87 % (κ = 0.48)Miller et al. 2022Validation study · abstract + full text
Apple Watch S6Sleep stages (wake, light, deep, REM)SleepSleepAgreement (epochs)53 % (κ = 0.20)Miller et al. 2022Validation study · abstract + full text
Garmin Forerunner 245 MusicSleep stages (wake, light, deep, REM)SleepSleepAgreement (epochs)50 % (κ = 0.25)Miller et al. 2022Validation study · abstract + full text
Polar Vantage VSleep stages (wake, light, deep, REM)SleepSleepAgreement (epochs)51 % (κ = 0.28)Miller et al. 2022Validation study · abstract + full text
Oura Ring Gen 2Sleep stages (wake, light, deep, REM)SleepSleepAgreement (epochs)61 % (κ = 0.43)Miller et al. 2022Validation study · abstract + full text
WHOOP 3.0Sleep stages (wake, light, deep, REM)SleepSleepAgreement (epochs)60 % (κ = 0.44)Miller et al. 2022Validation study · abstract + full text
SomfitSleep stages (wake, light, deep, REM)SleepSleepAgreement (epochs)65 % (κ = 0.52)Miller et al. 2022Validation study · abstract + full text
7 Geräte (Bereich)Sleep detectedSleepSleepSensitivity (epochs)≥ 0.93Chinoy et al. 2021Validation study · abstract only
7 Geräte (Bereich)Wake detectedSleepSleepSpecificity (epochs)0.18–0.54Chinoy et al. 2021Validation study · abstract only
Garmin VivosmartTotal sleep timeSleepSleepBias vs PSG (qualitative)worse than actigraphyKainec et al. 2024Validation study · abstract only
Fitbit Inspire, Fitbit Versa, Oura Ring, Withings MatTotal sleep timeSleepSleepBias vs PSG (qualitative)comparable to actigraphyKainec et al. 2024Validation study · abstract only
alle 5 GeräteREM sleepSleepSleepBias vs PSG (qualitative)lowKainec et al. 2024Validation study · abstract only
gepoolt (Handgelenk-Tracker)Total sleep timeSleepSleepmean difference (min, 95% CI)−16.9 [−26.3; −7.4]Lee et al. 2025Meta-analysis · abstract only
gepoolt (Handgelenk-Tracker)Sleep efficiencySleepSleepmean difference (percentage points, 95% CI)−4.7 [−7.1; −2.3]Lee et al. 2025Meta-analysis · abstract only
gepoolt (Handgelenk-Tracker)Sleep latencySleepSleepmean difference (min, 95% CI)+2.6 [0.6; 4.5]Lee et al. 2025Meta-analysis · abstract only
gepoolt (Handgelenk-Tracker)Wake after sleep onsetSleepSleepmean difference (min, 95% CI)+13.3 [4.5; 22.0]Lee et al. 2025Meta-analysis · abstract only
gepooltTotal sleep time, sleep efficiency, wakeSleepSleepDirection of biasTST/SE over-, WASO underestimatedAgostinho et al. 2026Meta-analysis · abstract only

Studies in this area

  1. Miller et al. 2022: A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults

    Sensors · Validation study · 53 adults, one night (9 h in bed) · DOI 10.3390/s22166317

    All six devices agreed with polysomnography 86–89% of the time for “asleep or awake”, but only 50–65% for sleep stages. Devices that recorded heart rate during sleep showed high agreement for heart rate and moderate to high agreement for HRV.

  2. Chinoy et al. 2021: Performance of seven consumer sleep-tracking devices compared with polysomnography

    Sleep · Validation study · 34 adults, three nights incl. a disrupted night · DOI 10.1093/sleep/zsaa291

    All devices detected sleep reliably (sensitivity ≥ 0.93), wake much less so (specificity 0.18–0.54). Most devices were at least as good as actigraphy, the two Garmin models worse. All devices performed worse on disrupted nights.

  3. Kainec et al. 2024: Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography

    Sensors · Validation study · 53 young adults, one night · DOI 10.3390/s24020635

    All devices except the Garmin Vivosmart estimated total sleep time comparably to research-grade actigraphy. All overestimated nights with short wake times and underestimated nights with long ones. Proportional biases were common.

  4. Lee et al. 2025: Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis

    Journal of Clinical Sleep Medicine · Meta-analysis · 24 studies, 798 participants · DOI 10.5664/jcsm.11460

    Across all wrist-worn trackers, devices underestimated total sleep time and sleep efficiency and overestimated wake after sleep onset. Fitbit did not differ significantly from polysomnography for wake after sleep onset.

  5. Agostinho et al. 2026: Are Wearable Sleep-Tracking Devices Reliable Alternatives to Polysomnography? A Systematic Review and Meta-Analysis

    Behavioral Sleep Medicine · Meta-analysis · 16 studies, 10 in the meta-analysis · DOI 10.1080/15402002.2026.2673893

    Wearables overestimated total sleep time and sleep efficiency and underestimated wake, with large variability between devices. No device was consistently superior. Reasonable for global sleep metrics, not suitable as a stand-alone diagnostic tool or for sleep stages.