Study profile · Chinoy et al. 2021
Performance of seven consumer sleep-tracking devices compared with polysomnography
All devices detected sleep reliably (sensitivity ≥ 0.93), wake much less so (specificity 0.18–0.54). Most devices were at least as good as actigraphy, the two Garmin models worse. All devices performed worse on disrupted nights.
Chinoy ED, Cuellar JA, Huwa KE, et al. · Sleep 2021 · DOI 10.1093/sleep/zsaa291 · PubMed 33378539
Fact sheet
- Study type
- Validation study · peer-reviewed
- Sample
- 34 adults, three nights incl. a disrupted night
- Population
- Healthy young adults (28.1 ± 3.9 years), sleep lab
- Reference method
- Polysomnography; plus actigraphy (Actiwatch 2)
- Devices
- Fatigue Science Readiband, Fitbit Alta HR, Garmin Fenix 5S, Garmin Vivosmart 3, EarlySense Live, ResMed S+, SleepScore Max
- Funding
- not stated in the abstract
- Extraction
- abstract only – full-text details deliberately omitted
- Checked on
- 2026-11-17
Limitations: Small, young, healthy sample; not every device worn every night.
Results in the register
| Device | Metric | Situation | Error measure (original) | Result |
|---|---|---|---|---|
| 7 Geräte (Bereich) | Sleep detectedSleep | Sleep | Sensitivity (epochs) | ≥ 0.93 |
| 7 Geräte (Bereich) | Wake detectedSleep | Sleep | Specificity (epochs) | 0.18–0.54 |
Original source: Chinoy ED, Cuellar JA, Huwa KE, et al. (2021): Performance of seven consumer sleep-tracking devices compared with polysomnography. Sleep.