Study profile · Lee et al. 2025
Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis
Across all wrist-worn trackers, devices underestimated total sleep time and sleep efficiency and overestimated wake after sleep onset. Fitbit did not differ significantly from polysomnography for wake after sleep onset.
Lee YJ, Lee JY, Cho JH, Kang YJ, Choi JH · Journal of Clinical Sleep Medicine 2025 · DOI 10.5664/jcsm.11460 · PubMed 39484805
Fact sheet
- Study type
- Meta-analysis · peer-reviewed
- Sample
- 24 studies, 798 participants
- Population
- Participants from 24 studies up to March 2024
- Reference method
- Polysomnography
- Devices
- Fitbit, Jawbone, myCadian watch, WHOOP strap, Garmin, Basis B1, Zulu Watch, Huami Arc, E4 wristband, Fatigue Science Readiband, Apple Watch, Xiaomi Mi Band 5
- Funding
- not stated in the abstract
- Extraction
- abstract only – full-text details deliberately omitted
- Checked on
- 2026-11-17
Limitations: Pooled values across very different devices and generations.
Results in the register
| Device | Metric | Situation | Error measure (original) | Result |
|---|---|---|---|---|
| gepoolt (Handgelenk-Tracker) | Total sleep timeSleep | Sleep | mean difference (min, 95% CI) | −16.9 [−26.3; −7.4] |
| gepoolt (Handgelenk-Tracker) | Sleep efficiencySleep | Sleep | mean difference (percentage points, 95% CI) | −4.7 [−7.1; −2.3] |
| gepoolt (Handgelenk-Tracker) | Sleep latencySleep | Sleep | mean difference (min, 95% CI) | +2.6 [0.6; 4.5] |
| gepoolt (Handgelenk-Tracker) | Wake after sleep onsetSleep | Sleep | mean difference (min, 95% CI) | +13.3 [4.5; 22.0] |