Performance of seven consumer sleep-tracking devices compared with polysomnography

All devices detected sleep reliably (sensitivity ≥ 0.93), wake much less so (specificity 0.18–0.54). Most devices were at least as good as actigraphy, the two Garmin models worse. All devices performed worse on disrupted nights.

Chinoy ED, Cuellar JA, Huwa KE, et al. · Sleep 2021 · DOI 10.1093/sleep/zsaa291 · PubMed 33378539

Fact sheet

Study type
Validation study · peer-reviewed
Sample
34 adults, three nights incl. a disrupted night
Population
Healthy young adults (28.1 ± 3.9 years), sleep lab
Reference method
Polysomnography; plus actigraphy (Actiwatch 2)
Devices
Fatigue Science Readiband, Fitbit Alta HR, Garmin Fenix 5S, Garmin Vivosmart 3, EarlySense Live, ResMed S+, SleepScore Max
Funding
not stated in the abstract
Extraction
abstract only – full-text details deliberately omitted
Checked on
2026-11-17

Limitations: Small, young, healthy sample; not every device worn every night.

Results in the register

DeviceMetricSituationError measure (original)Result
7 Geräte (Bereich)Sleep detectedSleepSleepSensitivity (epochs)≥ 0.93
7 Geräte (Bereich)Wake detectedSleepSleepSpecificity (epochs)0.18–0.54

Original source: Chinoy ED, Cuellar JA, Huwa KE, et al. (2021): Performance of seven consumer sleep-tracking devices compared with polysomnography. Sleep.