Syrax Wearable Evidence Index
Sleep: How accurate are wearables? Studies at a glance
Sleep trackers are tested against polysomnography (PSG) in a sleep lab. They reliably detect whether someone is asleep, but much less well when someone lies awake. Agreement for individual sleep stages is rough.
5 studies · 22 results
Results
22 results
| Device | Metric | Situation | Error measure (original) | Result | Study |
|---|---|---|---|---|---|
| Apple Watch S6 | Sleep/wake detectionSleep | Sleep | Agreement (epochs) | 88 % (κ = 0.30) | Miller et al. 2022Validation study · abstract + full text |
| Garmin Forerunner 245 Music | Sleep/wake detectionSleep | Sleep | Agreement (epochs) | 89 % (κ = 0.35) | Miller et al. 2022Validation study · abstract + full text |
| Polar Vantage V | Sleep/wake detectionSleep | Sleep | Agreement (epochs) | 87 % (κ = 0.44) | Miller et al. 2022Validation study · abstract + full text |
| Oura Ring Gen 2 | Sleep/wake detectionSleep | Sleep | Agreement (epochs) | 89 % (κ = 0.51) | Miller et al. 2022Validation study · abstract + full text |
| WHOOP 3.0 | Sleep/wake detectionSleep | Sleep | Agreement (epochs) | 86 % (κ = 0.44) | Miller et al. 2022Validation study · abstract + full text |
| Somfit | Sleep/wake detectionSleep | Sleep | Agreement (epochs) | 87 % (κ = 0.48) | Miller et al. 2022Validation study · abstract + full text |
| Apple Watch S6 | Sleep stages (wake, light, deep, REM)Sleep | Sleep | Agreement (epochs) | 53 % (κ = 0.20) | Miller et al. 2022Validation study · abstract + full text |
| Garmin Forerunner 245 Music | Sleep stages (wake, light, deep, REM)Sleep | Sleep | Agreement (epochs) | 50 % (κ = 0.25) | Miller et al. 2022Validation study · abstract + full text |
| Polar Vantage V | Sleep stages (wake, light, deep, REM)Sleep | Sleep | Agreement (epochs) | 51 % (κ = 0.28) | Miller et al. 2022Validation study · abstract + full text |
| Oura Ring Gen 2 | Sleep stages (wake, light, deep, REM)Sleep | Sleep | Agreement (epochs) | 61 % (κ = 0.43) | Miller et al. 2022Validation study · abstract + full text |
| WHOOP 3.0 | Sleep stages (wake, light, deep, REM)Sleep | Sleep | Agreement (epochs) | 60 % (κ = 0.44) | Miller et al. 2022Validation study · abstract + full text |
| Somfit | Sleep stages (wake, light, deep, REM)Sleep | Sleep | Agreement (epochs) | 65 % (κ = 0.52) | Miller et al. 2022Validation study · abstract + full text |
| 7 Geräte (Bereich) | Sleep detectedSleep | Sleep | Sensitivity (epochs) | ≥ 0.93 | Chinoy et al. 2021Validation study · abstract only |
| 7 Geräte (Bereich) | Wake detectedSleep | Sleep | Specificity (epochs) | 0.18–0.54 | Chinoy et al. 2021Validation study · abstract only |
| Garmin Vivosmart | Total sleep timeSleep | Sleep | Bias vs PSG (qualitative) | worse than actigraphy | Kainec et al. 2024Validation study · abstract only |
| Fitbit Inspire, Fitbit Versa, Oura Ring, Withings Mat | Total sleep timeSleep | Sleep | Bias vs PSG (qualitative) | comparable to actigraphy | Kainec et al. 2024Validation study · abstract only |
| alle 5 Geräte | REM sleepSleep | Sleep | Bias vs PSG (qualitative) | low | Kainec et al. 2024Validation study · abstract only |
| gepoolt (Handgelenk-Tracker) | Total sleep timeSleep | Sleep | mean difference (min, 95% CI) | −16.9 [−26.3; −7.4] | Lee et al. 2025Meta-analysis · abstract only |
| gepoolt (Handgelenk-Tracker) | Sleep efficiencySleep | Sleep | mean difference (percentage points, 95% CI) | −4.7 [−7.1; −2.3] | Lee et al. 2025Meta-analysis · abstract only |
| gepoolt (Handgelenk-Tracker) | Sleep latencySleep | Sleep | mean difference (min, 95% CI) | +2.6 [0.6; 4.5] | Lee et al. 2025Meta-analysis · abstract only |
| gepoolt (Handgelenk-Tracker) | Wake after sleep onsetSleep | Sleep | mean difference (min, 95% CI) | +13.3 [4.5; 22.0] | Lee et al. 2025Meta-analysis · abstract only |
| gepoolt | Total sleep time, sleep efficiency, wakeSleep | Sleep | Direction of bias | TST/SE over-, WASO underestimated | Agostinho et al. 2026Meta-analysis · abstract only |
Studies in this area
Miller et al. 2022: A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults
Sensors · Validation study · 53 adults, one night (9 h in bed) · DOI 10.3390/s22166317
All six devices agreed with polysomnography 86–89% of the time for “asleep or awake”, but only 50–65% for sleep stages. Devices that recorded heart rate during sleep showed high agreement for heart rate and moderate to high agreement for HRV.
Chinoy et al. 2021: Performance of seven consumer sleep-tracking devices compared with polysomnography
Sleep · Validation study · 34 adults, three nights incl. a disrupted night · DOI 10.1093/sleep/zsaa291
All devices detected sleep reliably (sensitivity ≥ 0.93), wake much less so (specificity 0.18–0.54). Most devices were at least as good as actigraphy, the two Garmin models worse. All devices performed worse on disrupted nights.
Kainec et al. 2024: Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography
Sensors · Validation study · 53 young adults, one night · DOI 10.3390/s24020635
All devices except the Garmin Vivosmart estimated total sleep time comparably to research-grade actigraphy. All overestimated nights with short wake times and underestimated nights with long ones. Proportional biases were common.
Lee et al. 2025: Performance of consumer wrist-worn sleep tracking devices compared to polysomnography: a meta-analysis
Journal of Clinical Sleep Medicine · Meta-analysis · 24 studies, 798 participants · DOI 10.5664/jcsm.11460
Across all wrist-worn trackers, devices underestimated total sleep time and sleep efficiency and overestimated wake after sleep onset. Fitbit did not differ significantly from polysomnography for wake after sleep onset.
Agostinho et al. 2026: Are Wearable Sleep-Tracking Devices Reliable Alternatives to Polysomnography? A Systematic Review and Meta-Analysis
Behavioral Sleep Medicine · Meta-analysis · 16 studies, 10 in the meta-analysis · DOI 10.1080/15402002.2026.2673893
Wearables overestimated total sleep time and sleep efficiency and underestimated wake, with large variability between devices. No device was consistently superior. Reasonable for global sleep metrics, not suitable as a stand-alone diagnostic tool or for sleep stages.